LOK16.250A27,LOK16.140A27西门子控制器

发布
上海翼乾实业有限公司
价格
¥2850.00/个
供应
5000个
电话
021-51601969
手机
13764878996
发布时间
2014-04-15 16:19:00
产品详情
LOK16.250A27,LOK16.140A27西门子控制器



产品说明:

LOK16系列燃油燃烧器控制器

品牌:SIEMENS(西门子)

产地:德国

产品介绍

Burner controls type LOK16... feature a self-checking flame supervision circuit. That supervision circuit initiates the required safety actions not only in the case of premature or missing flame signals, but also in the event of any kind of fault on the flame detector, the detector cables or the flame signal amplifier that could simulate a flame signal during burner operation.

The burner controls are therefore suited for use in all types of oil-fired combustion plants where self-checking flame supervision systems are either mandatory or recommendable:

Burners that operate continuously

Burners in intermittent operation that, in the case of great heat demand, may operate continuously for more than 14 hours, e.g. in plants using boiler sequencing

Burners that need to comply with the German TRD 411 and TRD 412 regulations for steam boilers

Burners in plants where, for specific safety re, supervision of the burner by a self-checking flame supervision system seems advisable

型号表

  LOK16.140A27 LOK16.250A27 LOK16.650A27 注释

快速式 通用式 重油式

t1 10 22.5 67.5 预吹扫时间(风门全开时)

TSA 4 5 5 安全时间

TSA’ - - - 安全时间

t3 2 2.5 2.5 预点火时间

t3’ 从启动命令开始(如果带有空气压力监测,从接受到空气压力监控信号开始) 长预点火时间

t3n 10 15 15 后点火时间(点火变压器连接端口15)

t4 8 7.5 7.5 从TSA开始到端口19的阀打开的间隔时间

t4’ - - - 从TSA开始到端口19的阀打开的间隔时间

t5 4 7.5 7.5 从t4结束到比例调节或端口20的阀门打开的间隔时间

t6 10 15 15 后吹扫时间

t7 2 2.5 2.5 打开风机马达2的延迟时间

t8 30 47.5 92.5 没有t11和t12时,整个启动阶段时间

t9 - - - 第二安全时间

t10 6 10 10 从启动到空气压力监测开始工作的间隔时间

t11 Optional 风门打开到最大位置的时间

t12 Optional 风门至小火位置的时间

t13 可允许的燃烧后时间

t16 4 5 5 从启动到风门打开命令的间隔时间

t20 32 35 12.5 锁定后程序内部循环时间