德国西门子LAL2.14 LAL2.25燃油燃烧器控制器

发布
深圳市宝安区石岩天达涂装设备配销售部
供应
100
电话
0755-29722030
手机
13590142700
发布时间
2013-11-22 16:36:00
产品详情
德国进口控制器 西门子控制器 SIEMENS控制器 程序控制器价格 控制器技术参数 控制器批发 燃烧器控制器 控制器详细信息 西门子程序控制器 燃烧器配件



品牌:SIEMENS(西门子)

产地:德国

 产品介绍

Oil burner controls

With / without air pressure check for checked air damper control

Flame supervision with



photoresistive detectors

blue-flame detectors , or

selenium photocell detectors RAR...

The oil burner controls LAL... are tested and certified to EN 230. They carry the CE mark in compliance with the directives for electromagnetic compatibility!

The LAL... and this data sheet are intended for use by OEMs which integrate the burner controls in their products!

Control and supervision of oil atomization burners

For burners of medium to high capacity

For intermittent operation (at least one controlled shutdown every 24 hours)

Universally applicable for multistage or modulating burners

For burners of stationary air heaters (WLE to DIN 4794)

 型号表

  快速蒸发型 通用型 重油燃烧器用

火焰检测使用或(兰色火焰) LAL1.25

LAL4.25A27

火焰检测使用或RAR... LAL2.14 LAL2.25 LAL2.65

可用空气压力监测

可用半自动启动

同LAL2.25,带有以下特征:外来光线不导致燃烧器锁定,只会阻止燃烧器启动 LAL3.25

t1 10s 22.5s 67.5s

t2 4s 5s 5s

t3 2s 2.5s 2.5s

t3’ 从空气监测器收到信号开始 从空气监测器收到信号开始 从空气监测器收到信号开始

t3n 10s 15s 15s

t4 8s 7.5s 7.5s

t5 4s 7.5s 7.5s

t6 10s 15s 15s

t7 2s 2.5s 2.5s

t8 30s 47.5s 92.5s

t10 6s 10s 10s

t11 运行 运行 运行

t12 运行 运行 运行

t13 10s 15s 15s

t16 4s 5s 5s

t20 32s 35s 12.5s



t1 :风门全开后的预吹扫时间

- 在t1时间内,火焰监测循环开始工作

- 如果有故障,燃烧器开始锁定

对于LAL2.../LAL3.../LAL4... 从t1开始后不久,空气压力监测必须从端口13转到端口14

TSA 点火安全时间

在TSA结束后,一个正常的火焰必须被端口22检测到。而且必须是稳定的信号,直到燃烧器被关闭

否则,燃烧器控制将被锁定。

t3 短预点火时间

点火变压器必须被连接至端口16,端口18的电磁阀门也必须在打开状态

t3’ 长预点火时间

点火变压器必须被