嘉禾矿用防爆电缆MKVVRP2X0.5格坚强
Low-smoke halogen free cables should be used in subway, underground, control centers, schools, shopping malls, office buildings and other places. Belongs to the new environmental protection wire and cable.
DJYVP3 聚乙烯绝缘对绞铝塑复合带总屏蔽聚氯乙烯 护套计算机电缆 敷设室内、电缆沟、管道等要求静电屏蔽场合。DJYP3VP3 聚乙烯绝缘对绞铝塑复合带分屏蔽及总屏蔽聚氯乙烯护套计算机电缆 敷设室内、电缆沟、管道等要求静电屏蔽场合。
ZR-VV22ZR-VLV22聚氯乙烯绝缘钢带铠装聚氯乙烯 敷设在室内、隧道及 护套阻燃电力电缆 直埋土壤中,电缆能承 。
S:单编织屏蔽层,D:双编织屏蔽层*铠装电缆电缆型号标称阻抗Ω直径尺寸Φ(mm)内导体绝缘层屏蔽层护套构成外径SYV-50-1507×0.10.270.87±0.051.40S1.9±0.10SYV507×0.160.451.5±0.102.10S2。
电缆型号、名称、规格及用途型号名称规格用途MHYV(PUYV)聚乙烯绝缘阻燃聚氯乙烯护套矿用信号电缆2-57/0.28用于平巷、斜巷及机电耍硐室MHJYV(PUJYV)聚乙烯绝缘阻燃聚氯乙烯护套加强矿用通讯电缆2-57/0.28(三钢四铜)用于平巷、斜巷、有较好的抗拉强度MHYVP煤矿用聚乙烯绝缘编。
使用塑料线直接插入插座(未使用插头)正确做法:规范接线,使用正规插头现场三级电源箱一闸多用(一个插座用并用多个电动工具)正确做法:每台用电设备,有各自专用的开关箱,实行“一机一闸一保护”制,即开关箱必须是“一机、一闸、一漏、一箱”。严禁用同一开关电器直接控制两台或两台以上用电设备。现场拉设的临时电源线缆直接横跨上(挂在金属构件上)正确做法:采取保护措施,规范敷设路线,防止损伤伤人。电源线混乱、“拖地”现象严重。
3. 绝缘厚度:3.3线芯绝缘厚度为0.5,绝缘后外径为3.5毫米。0.85线芯绝缘厚度为0.7绝缘后外径为2.5毫米。4. 成缆时把四根线芯排列为红,绿,蓝,白,排流线,排流线要和线芯一起绞合,千万不要纵放,成缆时不要加填充物,缆芯外用铝箔绕包,而后再绕包一层聚酯膜,在外有一层铜丝编织屏蔽(屏蔽铜丝不镀锡)。
敷设方式:架空/管道/直埋。EISC-S铜芯聚乙烯绝缘,聚氯乙烯护套二芯绞合屏蔽,阻燃防本质安全电缆敷设在室内.电缆沟管道的固定场合。EISC-S22铜芯聚乙烯绝缘,聚氯乙烯护套二芯绞合屏蔽,阻燃内钢带铠装本质安全电缆敷设在室内.电缆沟管道内,直埋能承受较大机械外力等固定场合。
Precautions for installation of power cables: keep 2m distance when the cable is installed in parallel with the thermal pipe, and 0.5m should be maintained when crossing. The cable shall be installed at a distance of 0.5m in parallel or across other pipelines. When the cable is directly buried and installed, the direct buried depth of 1-35kv cable is less than 0.7m. When 10KV and below cables are installed in parallel, the net distance between them shall not be less than 0.1m and 10-35kv shall not be less than 0.25m. The distance of cross installation is not less than 0.5m. Cable laying temperature lower than 0 ℃, bending radius: multi-core cable or 15 (D + D), a single cable 20 or more (D + D), (D for cable diameter, D) for the conductor diameter. ? 6KV and above cable connector:? When installing the terminal head of the cable, the semiconductor electrical shielding layer must be stripped off. During operation, the insulation shall not be damaged. The shield end should be flat and the graphite layer (carbon particles) should be clean. (2) plastic cable end copper tape screened and armor must be good grounding, the short circuit also follow this principle, avoid unbalanced three-phase run ShiGang armoured end produce inductive electromotive force, and even "lighter" and sheath and other accidents. It is required to use my tinplate to braid copper wire for grounding lead. When connecting with the cable copper belt, it should be welded with chromium-iron tin. ? The shield of three-phase copper tape should be connected with ground wire respectively. Note that the shielded ground wire and steel armor ground wire should be separately drawn out and insulated from each other. The position of the welded ground wire should be as low as possible. Basic re for cable terminals and intermediate joints: a. good conductor connection; B. The insulation is reliable, and it is recommended to use irradiated cross-linked heat-shrinkable silicone rubber insulation materials; C. good sealing; D. sufficient mechanical strength to meet various operating conditions. The end of the cable must be used to prevent water and other corrosive materials from corroding, in order to prevent the water tree caused by the aging of the insulation layer and breakdown. Crane or forklift should be used for the loading and unloading of cables. It is forbidden to run flat or lay flat. For installation of large cables, cable laying cart should be used to avoid external damage or abrasion caused by manual dragging. If the cable cannot be laid in time for some reason, it should be stored in a dry place to prevent sunlight from exploding and water entering the end of the cable. ? Note: the installation of wire and cable should be familiar with the performance of wire and cable installation personnel or full-time technical personnel, if there are still unclear matters, ball related technical department or technical department of our factory.
三、使用特性 1、电缆长期工作温度:-30~60℃ 2、电缆敷设温度: 不低于0℃3、MHYV型弯曲半径不小于电缆直径的10倍。MHYBV型弯曲半径不小于电缆直径的10倍。MHYVP型弯曲半径不小于电缆直径的10倍。
同轴射频电缆SYV系列SYV-75-3|SYV-75-5|SYV-75-12|SYV-75-4|SYV-75-7|SYV-75-9|SYV-50-2|SYV-50-3|SYV-50-5|SYV-50-7|SYV-50-9|SYV-50-12|SYV-50-15|SYV-50-17|SYV-75-15。
采用对绞、对屏、总屏(或三线组合、组屏蔽、组屏总屏)等结构形式,具有介质损耗小、传输传号能力强、抗干扰性能好等特点,能可靠地传输微弱的模拟信号,可广泛地应用于发电、冶金、石油、化工、轻纺等部门的检测和控制用计算机系统或自动化装置,以及一般的工业计算机上。
C:电缆的弯头半径做到尽可能大。伺服电机允许的轴端负载A:确保在安装和运转时加到伺服电机轴上的径向和轴向负载控制在每种型号的规定值以内。B:在安装一个刚性联轴器时要格外小心,特别是过度的弯曲负载可能导致轴端和轴承的损坏或磨损。C:**用柔性联轴器,以便使径向负载低于允许值,此物是专为高机械强度的伺服电机设计的。D:关于允许轴负载,请参阅“允许的轴负荷表”。伺服电机安装注意A:在安装/拆卸耦合部件到伺服电机轴端时,不要用锤子直接敲打轴端。
SYV视频线、SYWV电视天线、RVVP屏蔽线、RVV护套线、AVVR多芯信号线、多芯音频线、RVSP双绞屏蔽线、各种屏蔽线缆、各种护套电源线、五类网络线、超五类网线、同轴电缆、各种监控线缆、各种弱电线缆 、各种高压电缆、各种射频、视频、同轴电缆、多芯视频电缆、多芯音频线、各规格、音响线、各种话筒线。
RVSP屏蔽双绞线;RVSP屏蔽双绞电缆RVSP(屏蔽双绞线,屏蔽电缆,屏蔽双绞电缆屏蔽双绞铠装电缆,并可提供屏蔽双绞铠装电缆技术咨询和屏蔽双绞铠装电缆的结构尺寸屏蔽双绞铠装电缆-屏蔽双绞铠装电缆大全-专业生产屏蔽双绞铠装电缆大型企业屏蔽双绞铠装电缆-屏蔽双绞铠装电缆大全-专业生产屏蔽双绞铠装电缆.。