RVVZ3X6平方电缆外皮黑色赤坎更多活动****SYV射频电缆起火
自承式电缆结构:导线:退火裸铜线,铜线直径为0.32,0.4,0.5,0.6,0.7,0.8,0.9mm。绝缘材料:高密度聚乙烯或乙/丙共聚物,绝缘现的颜色符合全色谱标准。绝缘线对:二根不同颜色的绝缘线按不同的节距扭绞成对,采用规定的 HYAC-索道通信电缆-的详细介绍色谱组合以便识别。
1、产品名称:自承式控制电缆KVVRC行车控制电缆2、型号:KVVRC、KVVPRC、KVVP2RC、KVVRPRC3、产品说明:型号名称KVVRC自承式铜芯聚氯乙烯绝缘聚氯乙烯护套行车控制电缆KVVPRC自承式铜芯聚氯乙烯绝缘聚氯乙烯护套编织屏蔽行车专用电缆KVVP2RC自承式铜芯聚氯乙烯绝缘聚氯。
销售生产各类煤矿用阻燃通信电缆、矿用通讯电缆,矿用信号电缆,煤矿用阻燃信号电缆、矿用阻燃控制电缆,煤矿用阻燃通讯电缆、矿用电缆、矿用通信电缆、矿用信号电缆、矿用通讯电缆、矿用通信电缆,矿用控制电缆,矿用监控电缆、传感器电缆、信号电缆、本安防爆电缆、控制电缆、计算机电缆、阻燃电缆、耐火电缆,市内通信电。
3、产品型号规格及范围:产品型号规格范围使用场合MKVV,MKVVP,MKVVP20.5-10mm2,2-61芯适用于弱电控制系统或强电磁场干扰区MKVV22,MKVV200.5-10mm2,4-61芯MKVV32,MKVV300.5-10mm2,7-61芯MKVVR0.5-6mm2,2-61芯MK。
识别和长度标记:电缆外表面有**性识别标记,标记间隔不大于1m,标记内容有:导线直径,线对数量,电缆型号,制造厂厂名代号及制造年份,长度标记以间隔不大于1m标记在外表面上,但与上述标记错开。总线电缆技术要求型号:HYVPVV2×6×0.8+3×2.5使用条件:-40℃~65℃,相对湿度£98%。
严格按照规范要求,做好专业巡检维护、通信自动化系统软硬件及数据维护和应急管理,防范“数据异常跳变”、链路中断和自动化系统失灵事件发生。做好外包队伍二次系统作业管理。从外包单位和人员资质审核、人员安全教育、施工方案审批、作业许可、过程监督、投产验收等全过程管理,同部署、同标准、同培训、同考核,防止因外包作业导致的误触碰、误动作或其它人为责任事件发生。各位电工朋友,关于电工二次系统的运行维护,您有什么好的建议,欢迎您留言分享。
MHY32(PUYV39-1) (1×2 1×4 2×2 3×2 4×2 5×2 6×2 8×2 10×2)1/1.0、1/1.38聚乙烯绝缘钢丝铠装聚氯乙烯护套煤矿用信号电缆用于平巷或竖井或斜井作信号传输。
Low-smoke halogen free cables should be used in subway, underground, control centers, schools, shopping malls, office buildings and other places. Belongs to the new environmental protection wire and cable.
Precautions for installation of power cables: keep 2m distance when the cable is installed in parallel with the thermal pipe, and 0.5m should be maintained when crossing. The cable shall be installed at a distance of 0.5m in parallel or across other pipelines. When the cable is directly buried and installed, the buried depth of 1-35kv cable is not less than 0.7m. When 10KV and below cables are installed in parallel, the net distance between them shall not be less than 0.1m and 10-35kv shall not be less than 0.25m. The distance of cross installation is not less than 0.5m. Cable laying temperature is not lower than 0 ℃, bending radius: multi-core cable or 15 (D + D), a single cable 20 or more (D + D), (D for cable diameter, D) for the conductor diameter. 6 kv and above cable joint: (1) installing a cable terminal head, must be stripped semiconductor electric shielding layer, operation shall not damage the insulation, should avoid mark uneven situation, when necessary use sand paper to grind; The shield end should be flat and the graphite layer (carbon particles) should be cleaned. (2) plastic cable end copper tape screened and armor must be good grounding, the short circuit also follow this principle, avoid unbalanced three-phase run ShiGang armoured end produce inductive electromotive force, and even "lighter" and accidents such as burning sheath. It is required to use my tinplate to braid copper wire for grounding lead. When connecting with the cable copper belt, it should be welded with chromium-iron tin. The shield of three-phase copper tape should be connected with ground wire respectively. Note that the shielded ground wire and steel armor ground wire should be separately drawn out and insulated from each other. The position of the welded ground wire should be as low as possible. Basic re for cable terminals and intermediate joints: a. good conductor connection; B. The insulation is reliable, and it is recommended to use irradiated cross-linked heat-shrinkable silicone rubber insulation materials; C. good sealing; D. sufficient mechanical strength to meet various operating conditions. The end of the cable must be used to prevent erosion of water and other corrosive materials, so as to prevent breakdown due to the aging of the insulation layer caused by water trees. Crane or forklift should be used for the loading and unloading of cables. It is forbidden to run flat or lay flat. For installation of large cables, cable laying cart should be used to avoid external damage or abrasion caused by manual dragging. If the cable cannot be laid in time for some reason, it should be stored in a dry place to prevent sunlight from exploding and water entering the end of the cable. Note: the installation of wire and cable should be done by the installation personnel or full-time technical personnel familiar with the performance of wire and cable. If there are still unclear matters, please consult the relevant technical department or the technical department of our factory.
采用对绞、对屏、总屏(或三线组合、组屏蔽、组屏总屏)等结构形式,具有介质损耗小、传输传号能力强、抗干扰性能好等特点,能可靠地传输微弱的模拟信号,可广泛地应用于发电、冶金、石油、化工、轻纺等部门的检测和控制用计算机系统或自动化装置,以及一般的工业计算机上。
射频电缆按绝缘型式分类(1)实体绝缘电缆在这种电缆的内外导体之间全部填满实体高频电介质,大多数软同轴射频电缆都是采用这种绝缘型式。(2)空气绝缘电缆电缆的绝缘层中,除了支撑内外导体的一部分固体介质外,其余大部分体积均是空气。
DJVP2V(R)P2-22聚氯乙烯绝缘铜带绕包分屏总屏聚氯乙烯护套钢带铠装计算机用屏蔽(软)电缆。DJVV(R)P3-22聚氯乙烯绝缘铝塑复合带绕包总屏聚氯乙烯护套钢带铠装计算机用屏蔽(软)电缆。
仪表指示是否与刀开关,断路器对应。母排,线路各连接部位有无过热变色现象。如果在运行中检查仪表盘上三相负荷是否平衡、三相电压是否相同。配电柜和电器里面有无放电声和烧焦的异味。。带灭弧罩的断路器,刀开关三相灭弧罩是否完整无缺。这个很多缺陷应该很多都存在,还是应该引起重视。检查断路器有无过大噪声。9.母排绝缘夹有无损伤和歪斜,母排夹固定螺丝有无松脱。10.配电柜里面设备的表面是否清洁,接地连接是否正常良好。
This product USES features: 1.1 the use of the cable temperature - 40 ℃ ~ + 60 ℃. 1.2 cable conductor long-term working temperature shall not exceed + 70 ℃. Cable laying temperature 1.3: PVC sheathed cable should not below 0 ℃; Polyethylene outer sheath cable should be not less than 20 ℃. 1.4 allowable bending radius of cables: non-armoured cables shall be no less than 10 times of the outer diameter of cables; The armored cable shall not be less than 15 times the outer diameter of the cable. 1.5 the ideal shielding coefficient of comprehensive sheathed railway signal cable is less than 0.8; The ideal shielding coefficient of aluminum sheath railway signal cable is less than 0.3
5.电缆允许弯曲半径:非铠装电缆最小为电缆外径的6倍铜带屏蔽或钢带铠装电缆最小为电缆外径的12倍氟塑料绝缘和护套电缆最小为电缆外径的8倍四:基本型号及名称(ZR192-)KFF氟46(进口PFA)绝缘和护套控制电缆(ZR192-)KFFP氟46(进口PFA)绝缘和护套铜丝编织屏蔽控制电缆(ZR1。
KVVRP铜芯聚氯乙烯绝缘聚氯乙烯护套编织屏蔽控制软电缆。KVVP-22铜芯聚氯乙烯绝缘聚氯乙烯护套铜丝编织屏蔽钢带铠装KVVP2-22铜芯聚氯乙烯绝缘聚氯乙烯护套铜带屏蔽钢带铠装。--铜芯、实芯聚烯烃绝缘、铝塑综合护套市内通信电缆。
屏蔽对与屏蔽对具有较好的绝缘性能,电缆在使用中若屏蔽对屏蔽对之间出现电位差时,不会影响信号的传输质量。用于以电子计算机为主的自动控制系统,尤其适用于计算机集散控制系统,传递生产装置过程变量的检测、控制、联锁、报警等模拟和数字信号。