MK Battery is one of the largest sealed lead acid battery suppliers worldwide due to our total

commitment to the following core principles: MK Battery supplies only the highest batteries (gel, AGM and flooded deep cycle) that are specifically designed for our customers’ many, varied applications including broadband communications, UPS (uninterruptible power supplies), power wheelchairs, telephony (valve-regulated stationary), solar, marine and electronics. MK Battery ships fresh inventory fast, often within 24 hours, from a stock of more than 100,000 batteries in multiple distribution centers throughout the world and assists our.
美国MK蓄电池M45-12 SLD M MU产品系列说明
1) 体重比能量高,内阻小,输出功率高;
2) 充放电性能高,自放电控制在每个月2% 以下(20℃);
3) 恢复性能好 , 在深放电或者充电器出现故障时,短路放置30天后,仍可使用均衡充电法使其恢复容量  17、蓄电池的浮充电压是指在环境温度为25℃ 下充电电压值,当温差超过10℃ 时,必须修正浮充电压,否则会损伤蓄电池。环境温度升高1℃ ,应降低浮充电压0.003V/单格;相反,则升高浮充电压0.003V/单格。;
4) 由于单体电池的内阻、容量、浮充电压一致性好,充电时,应在外接一直流电源(充电极或整流器),使正、负极板在放电后生成的物质恢复成原来的活性物质,并把外界的电能转变为化学能储存起来。 因此电池在浮充使用状态下无需均衡充电。
6、温度适应性强: 可在-30℃~50℃下安全、放心地使用;
7、使用和运输安全简便: 满荷电出厂,无游离电解液,电池可横向放置,并可以无危险材料进行水、陆运输;
8、经济实惠: 柏克蓄电池极高的性能,超长的使用寿命,极低的维护成本确保用户得到的是经济实惠的产品。

1、当前电池放电技术分析
  1.1离线式放电法技术分析
  (1)将其中一组电池脱离系统后,一旦市电中断,系统备用电池供电时间明显缩短,何况此时尚不清楚另一组在线电池是否存在质量问题,此放电方式事故风险性高。如要用此方式放电,建议提前启用发动机组,并确保发电机组、开关电源等设备能正常运行,保证安全;美国MK蓄电池M45-12 SLD M MU产品系列说明
  (2)离线放电结束后的电池组与在线电池组间存在较大电压差,若操作不当将引起开关电源和在线电池组对离线放电后的电池组进行大电流充电,产生巨大火花,易发生安全事故。用此方式放电,需要配备一台整组智能充电机,对该离线电池组先充电恢复后再并联回系统,以解决打火花问题,这样将使系统更长时间处于单组供电状态,事故风险高。另通过调整整流器输出与被放电的电池组电压相等后进行恢复连接。上述操作一定要谨慎操作;
  (3)此放电方式操作时既要脱离电池组的正极,又要脱离电池组的负极,尤其是脱离电池组负极时需要特别小心,操作不当引起负极短路,将造成系统供电中断,导致通信事故的发生;
  (4)此方式是将电池通过假负载以热量形式消耗,浪费电能,影响机房设备运行环境,需要维护人员时刻守护以免高温引发事故。

Service 

"Ship fresh inventory within 24 hours from the nearest point to our customer while providing worry-free spent battery disposal." This is the MK Battery service axiom. Conse, we ship our products from more than 50 locations in North America, with additional facilities and distributors worldwide. Concerning recycling, MK Battery can assist with proper spent battery disposal through legally approved smelters. That is critical for you because hazardous waste disposal laws place heavy penalties on offenders. In summary, MK Battery understands the needs of our various markets and delivers products whenever and wherever they are needed.
美国MK蓄电池M45-12 SLD M MU产品系列说明
SPECIFICATIONS DIMENSIONS Nominal Voltage (V): 12V Nominal Capacity: 20hour rate ( 0.25A to 10.50V ) 5Ah 10hour rate ( 0.5A to 10.50V ) 4.75Ah 5hour rate ( 0.85A to 10.20V ) 4.25Ah 1C ( 5A to 9.60V ) 3.5Ah 3C ( 15A to 9.60V ) 2.55Ah W/Cell to 1.67 End Voltage (15 Min. Rate) 23 Weight: 4.43 Lbskg) Internal Resistance (at 1KHz): 18 m Maximum Discharge Current for 30 seconds: 100A Maximum Discharge Current for 5 seconds: 200A Operating Temperature Range: Charge 0°C(32°F) to 40°C (104°F) Discharge -15°C(5°F) to 50°C (122°F) Storage -15°C(5°F) to 40°C (104°F) Charge Retention (shelf life) at 20°C (68°F): 1 month 92% 3 month 90% 6 month 80% Charging Methods at 25°C (77°F) Cycle use: Charging Voltage 14.4 to 15.0V Maximum Charging Current 1.5A Standby use: Float Charging Voltage 13.50 to 13.80V Life expectancy Cycle Use: 100% depth of discharge 225 cycles 80% depth of discharge 250 cycles 50% depth of discharge 750 cycles Standby Use: 3~5 years Case Material ABS UL94-V0 flame retardant case/cover 
 UPS是不间断(uninterruptiblepowersystem)的英文简称,是能够提供持续、稳定、不间断的电源供应的重要外部设备。UPS按工作原理分成后备式、在线式与在线互动式三大类。UPS顾名思义,它就是一台这样的机器,它在市电停止供应的时候,能保持一段供电时间,使人们有时间存盘,再从容地关闭机器.
  1、雷电对于UPS电源的危害
  现如今市面上的UPS主要可分为两大类:未安装防雷器件的UPS与内部安装有防雷器件的UPS.未安装防雷器件的UPS,这类UPS包括早期生产和目前部份小功率的UPS,其防雷功能可以说“无”,只能对市电网过电压或很小的杂散电流起着电源净化的保护作用。当雷击来临时,它本身首当其冲被击坏。内部安装有防雷器件的UPS,这里分二种类型:装有不合标准的防雷器件的UPS,这类UPS生产厂家为了节省成本,只是象征性装一组小功率的金属氧化锌压敏电阻MOV,只能对很小的感应雷电有一定的防护作用。部分进口名牌UPS及几家国内着名UPS生产厂家在其UPS内部安装有标准的防雷器件,这一类UPS是否可以完善地保护UPS自身,并通过保护自身而达到保护其它设备电源的免遭雷电的侵害的目的呢?答案是否定的。
  关于雷电对于微电子设备的危害早已为工程技术人员所熟悉。对于微电子设备来讲,危害最大的是雷电电磁脉冲,它无孔不入,隐含杀机。根据我们对有关事故的统计表明,70%以上的雷击事故是从电源线侵入的,而UPS电源不能阻挡雷电流的侵入。
  (1)从2中的讨论可知,UPS电源的市电输入端口是滤波单元,一般包括MEI滤波器与RFI滤波器,而根据雷电流的<strong>频谱</strong>特点,其90%以上的能量集中于1MHz以下,直流成分占60%以上。当雷电来临,UPS位于电源线路的最前端,首当其中受到攻击。美国MK蓄电池M45-12 SLD M MU产品系列说明
  (2)现在不少UPS增加了避雷功能,其原理是在UPS的输入端增加一个MOV避雷模块,有些部分进口名牌UPS及几家国内着名UPS生产厂家在其UPS内部,根据国际IEC801-5的标准加装了避雷模块,抑制吸收电源供电线路输入端的雷电电压及电流的强浪涌,其冲击电流为20KA,冲击电压为6kV,波形为8/20无屏蔽地下电缆可达10kV,如果没有按照规范设计的完整的防雷体系,即是这样的UPS也无法保护用电设备不受雷电侵害的。
  (3)UPS电源,特别是智能化的UPS电源,本身含有大量的集成电路。而且越来越多的UPS带有智能管理系统,信号线也成为雷电电磁脉冲侵入的通道。正因为此,关于UPS电源遭受雷电侵害的案例屡见不鲜,特别是在雷暴日比较多的雷击区。
  如一台安装在海南某单位的UPS电源,自安装后运行半年均很正常,但是在遇到一次雷击以后,UPS就频繁出现在开机运行一段时间后,莫名奇妙地出现从逆变器供电自动转换到交流旁路电源供电的故障。
  从雷电灾害损失事例类型来看,而且基本上都有UPS电源。所以一定要对UPS电源及其监控系统的雷电防护引起足够的重视。