惠阳MCP-0.38/0.66采煤机屏蔽橡套软电缆5X1.5
Product introduction - plastic insulated control cable | | KVV control cable KVVR control cable | | KVVP control cable shielding control cable KVVP | | KVVRP shielding control cable KVVP2 control cable | | KVVP2-22 control cable KVV22 sheathed control cable | control cable KVV | control cable KVVR | control cable KVVP | control cable KVVRP | control cable KVV22 product details: plastic insulated control cable: GB9330-88 scope of application: This product is fit for ac rated voltage up to and including 450/750 control, monitoring circuit and protection circuit using features: 1, the conductor long-term allowed working temperature is 70 ℃. 2, when laying temperature 0 ℃ or higher. 3. Small bending radius: 4. For unarmored cable, it should be no less than 6 times the outer diameter of the cable. 5. The cable with armor or copper shield shall not be less than 12 times the outer diameter of the cable. 6. The soft cable with screen shielding structure shall not be less than 6 times the outer diameter of the cable. 7. Model and name: KVV copper core PVC insulated PVC sheath control cable
KVV22铜芯聚氯乙烯绝缘聚氯乙烯护套钢带铠装kvv22电缆450/7504-370.75-10敷设在室内,电缆沟、管道直埋等能承受较大机械外力的固定场合。KVVP阻燃铜芯聚氯乙烯绝缘聚氯乙烯护套kvvp电缆450/7504-370.75-10敷设在室内,电缆沟、管道等要求屏蔽的固定场合。
由于含卤阻燃电缆(包括阻燃电缆、低卤低烟阻燃电缆)在燃烧时会释放具有腐蚀性的卤酸气体,大大阻碍消防工作从而耽误救火时间并加剧火势蔓延,因此在人口密度较高的公众场所应尽量设计选用无卤低烟阻燃电缆。在人口密度较小的作业区可以选用任意一种阻燃电缆。阻燃电缆分为A、B、C3类,其中A类阻燃电缆性能较B、C类更优,价格也最贵。设计人员提供订货清册时应标明阻燃电缆的类别。从外观上无法区分阻燃电缆的A、B、C类别,只有靠制造厂家进行供货保证,因此在设计选用时应慎重选择电缆制造厂家。惠阳MCP-0.38/0.66采煤机屏蔽橡套软电缆5X1.5
8 x2x0 DJYVP3R. 75?? 8 x2x1. 0?? Fire retardant computer cable zr-djyvp22; ZR - DJYPV22; ZR - DJYPVP22 DJYVP3R? 1. Use (Q/NPDL 010-2003) this product is suitable for cables with high anti-performance requirements for electronic computer monitoring and is also suitable for cables with high anti-capability requirements for testing instruments and instruments. 2. Performance 1 rated voltage U0/U is 300/500v and below. 2 cable allows - 40 ℃ ~ + 55 ℃ temperature range. In use, the cable should prevent high temperature direct radiation or. 3 cable conductor long-term allowed working temperature is 70 ℃, the temperature under installation should not below 0 ℃. 4. Allowable bending radius of cables: the cable without armor layer shall not be less than 6 times of the outer diameter of cables, and the cable with armor layer shall not be less than 12 times of the outer diameter of cables. Logarithm model the number of nominal section was conductor structure/mm diameter 20 ℃ when the conductor resistance is not greater than Ω/km

This is the General Purpose Cable in the UL standard. The applicable safety standard is UL1581. The commercial and general test conditions are similar and are approved for use in Canada and the United States. There is no smoke concentration specification for general-purpose grade cables, which are generally only used for horizontal running of the same floor, but not for vertical wiring of the floor.
下图为极异性磁铁与各向同性磁铁的步进电机在12V额定电压下的阻尼特性的比较。据此,定位时间方面,使用极异性磁铁的稳定时间长。但若降低驱动电压(降低为8V),则如下图所示,极异性磁铁的稳定时间变短。磁铁强的电机调整激磁电压(电流)时,稳定时间将变小。上图为几种电流的暂态特性。电流在转子转速大时会减小,此为受到反电势的影响所致。各向同性磁铁与极异性磁铁的周期比较,后者变短,振荡次数相同约为4,后者的稳定时间变短。
无卤低烟阻燃电缆和含卤阻燃电缆相比,有低腐蚀、低烟的优点,但电性能及机械性能明显降低,所以在进行电缆敷设时,无卤低烟阻燃电缆应较含卤阻燃电缆有更大的弯曲半径。在进行电缆敷设设计时,不宜将非阻燃电缆和阻燃电缆并列敷设,不宜将不同阻燃类别的阻燃电缆并列敷设。
阻燃电缆标准:电缆涉及火灾安全的主要技术指标是CO2电缆的阻燃性、烟雾的密度和气体的有毒性。美国防火标准较关注前两个问题,但是欧洲和美国对火灾安全有着完全不同的观点。
美国传统的概念认为:火灾的根源在于一氧化碳(CO)毒气的产生以及其后的燃烧过程中CO转化为CO2的热释放,因此,控制燃烧过程中的热释放量可减少火灾的危害。欧洲传统以来深信:在燃烧中产生的卤酸(HCL)释放量、气体腐蚀性、烟雾浓度及气体毒性是决定人们能否安全脱离火灾现场的主要因素。
2)电缆的长期允许工作温度:RV-105型应不超过105℃;其他型号应不超过70℃4、电缆型号、名称和使用范围:RV铜芯聚氯乙烯绝缘连接软电缆(电线)连接用RVB铜芯聚氯乙烯绝缘平型连接软电缆(电线)连接用RVS铜芯聚氯乙烯绝缘绞型连接软电线连接用RVV铜芯聚氯乙烯绝缘聚氯乙烯护套圆型连。
二、执行标准 SPTL/QB2002.10-03三、使用特性 1.电缆导体的长期允许工作温度应不超过65℃,敷设环境温度应不低于0℃。2.电缆敷设安装允许弯曲半径非铠装电缆应不小于电缆外径的10倍;铠装电缆应不小于电缆外径的15倍。

如数控机床、电子设备、五金冲压、木材石材机械、玻璃与门窗机械、注塑机、机械(人)手、建筑机械、重型机械厂、汽车制造、起重运输设备、自动化仓库、码头等室内外环境需要的场所。控制、监控回路及保护线路,电器仪表、配电装置的信号传输、控制与测量的使用。
为了评定线缆的阻燃性能优劣,国际电工委员会分别制定了IEC60332-1、IEC60332-2和IEC60332-3三个标准。IEC60332-1和IEC60332-2分别用来评定单根线缆按倾斜和垂直布放时的阻燃能力(国内对应GB12666.3和GB12666.4标准)。IEC60332-3(国内对应GB12666.5-90)用来评定成束线缆垂直燃烧时的阻燃能力,相比之下成束线缆垂直燃烧时在阻燃能力的要求上要高得多。
IEC60332-1/BS4066-1阻燃等级(单根电线或电缆垂直燃烧测试FlameTestONSingleVerticalInsulatedWires/Cables)
下图充分说明了HB型混合式步进电机的结构和工作原理。转子磁路中间为**磁铁,下侧为N极,上侧为S极。磁铁的厚度方向磁通由上向下。开始状态为A相激磁,则“杠A”相极性相反,因此停在图示位置,转子与A相和“杠A”相的各一半对应,形成交链磁通Фm,如图中虚线所示。下一步,激磁相转换到状态,断开A相激磁电流,接通B相激磁电流,则转子向右移动1/4转子齿距,运行到图的位置。再一步,激磁相转换到状态,断开B相激磁,接通“杠A”相激磁,则转子从状态向右移动一步(1/4齿距)运行到状态的位置。
电缆的装卸必须使用吊车或叉车,禁止平运,平放,大型电缆安装时须使用放缆车,以免电缆受外力损伤或因人工拖动而擦伤。 电缆如因故不能及时敷设时,应将其放在干燥地方贮存,防止日光爆晒,电缆端头进水等。