This is the flame retardant standard for bundles of cables. According to the test regulations, the 3.5m long cable samples are fixed with iron wire on the trapezoid test frame, and the number of samples is determined according to the different classification requirements of non-metallic materials. The sample is hung vertically on the back wall of the furnace, and air is introduced into the furnace through the inlet on the bottom plate.
特性阻抗75Ω射频同轴电缆常用于CATV网,故称为CATV电缆,传输带宽可达1GHz,目前常用CATV电缆的传输带宽:750MHz。特性阻抗50Ω射频同轴电缆主要用于基带信号传输,传输带宽为1~2OMHz,一般特性阻抗50Ω细同轴电缆的最大传输距离为180米,粗同轴电缆可达1000米。
氟塑料绝缘和护套耐高温控制电缆采用聚全氟乙丙稀或改性聚四氟乙烯材料,具有比普通控制电缆更高的耐热等级。DJFVP:F46绝缘,聚氯乙烯护套铜丝总屏蔽高温防腐耐油计算机电缆。DJFPV:F46绝缘,聚氯乙烯护套铜丝分屏蔽高温防腐耐油计算机电缆。
Application: this product is suitable for fixed installation in mines, roadways, etc., as the main line of communication and connecting line between the junction box and telephone. HUVV copper core PVC insulated mine of telephone cable laying in the mine, the general situation of ground type polyethylene insulated PVC sheathed duct model name CPEV -s ground type polyethylene insulated PVC sheathed communication cable in the city

六.电缆的运输储存及注意事项:电缆适用于水.陆.空一切运输工具,在运输储存过程中应注意:1. 防止水分侵入电缆;2. 防止严重弯曲及其他机械损伤;3. 防止高温及阳光下暴晒;4. 电缆吊装应使用专用吊装设备,严禁平吊线盘或直接从高空推卸电缆。
从而控制外部两条独立的收发信号线RXD(P3.0)、TXD(P3.1),同时发送、接收数据,实现全双工。串行口控制寄存器SCON(见表1)。表1SCON寄存器表中各位(从左至右为从高位到低位)含义如下。SM0和SM1:串行口工作方式控制位,其定义如表2所示。表2串行口工作方式控制位其中,fOSC为单片机的时钟频率;波特率指串行口每秒钟发送(或接收)的位数。SM2:多机通信控制位。该仅用于方式2和方式3的多机通信。
同轴电缆(视频线,监控线,射频线)同轴电缆从用途上分可分为基带同轴电缆和宽带同轴电缆(即网络同轴电缆和视频同轴电缆)。同轴电缆分50Ω基带电缆和75Ω宽带电缆两类。基带电缆又分细同轴电缆和粗同轴电缆。基带电缆仅仅用于数字传输,数据率可达10Mbps。
电缆额定电压的选择●电缆的额定电压应适合于电缆系统的运行状况,用Uo/U(Um)KV表示。Uo--电缆设计用的导体对地或金属屏蔽之间的额定工频电压;U--电缆设计用的导体间的额定工频电压;Um--设备可承受的“最高系统电压”的最大值。
RVVSP shielded twisted-pair cable, used in the field lines, electrical instrumentation, telecommunications, broadcasting, anti-theft alarm system, building intercom system, video monitoring system, electronic equipment and automation devices such as shielding line. (transmission RS485 signals /) our factory new micro sales letter, micro signal: 15075619608 QQ is not convenient to micro letter contact! Conditions of use 1: using temperature (℃) : - 40 ~ 60 + 2: relative humidity: 98% at 40 ℃ 3: install the laying temperature is not low, such as: 15 ℃ 4: allowed minimum bending radius: indoor is not less than five times, 10 times outdoor structure 1:2: tinned copper wire line core PVC insulated/twisted-pair cable 3: film around the package/tin copper wire mesh grid block 4 PVC sheathed rated voltage: 300 v / 300 v, 300 v / 300 v with a standard: GB/T5023-1997 RVVP cable series: Can achieve 2 core to 24 core, line diameter has: 0.5, 0.75, 1.0, 1.5, 2.0, 2.5, 4.0, etc. (zr-rvvsp flame retardant),(nh-rvvsp fire resistance),(wdz-rvvsp low smoke halogen free) special model can be produced as required
EISC - SS fire-retardant explosion-proof intrinsically safe cable EISC - SS - R flame retardant. Explosion-proof intrinsically safe cable (wire) (business standard) the enterprise standard main technical indicators are reference articles IEC227 (1979) preparing publications and British BS5308Part1 standard materials. Purpose: this product is designed for laying sites with rated ac voltage of 450/750v or less, and strong anti-rf interference and anti-near field coupling ability for essential safety requirements. It is also suitable for distribution system and essential safety circuit signal transmission of industrial departments operating in gas explosion environment. Operating conditions: 1) rated voltage is 450/750v. 2) cable conductor long-term allowed working temperature is 70 ℃. 3) the cable temperature under installation should not below 0 ℃, allowed recommended no armoured cable bending radius should not less than 6 times of cable diameter. The armored cable shall not be less than 12 times the outer diameter of the cable.

同轴电缆SYV——实心聚乙烯绝缘,PVC护套,国标代号是射频电缆——又叫视频电缆.绝缘层物理特性不同:SYV是****聚乙烯填充,介电常数ε=2.2-2.4左右;而SYWV也是聚乙烯填充。一般所指的视频线为电视有线,也可用作安防领域的监控摄像头用线。
Specification range of frequency conversion cables; 1, some conclusions: 3 core nominal section (1.5 ~ 240 ㎜ 2). 2, some conclusions: 6 core (3 + 3) nominal section (thread core section: 2.5-240 ㎜ 2, line core section: 0.5 ㎜ 35 (2). Example: copper 0.6/1 kv crosslinked polyethylene insulated copper wire braided shielding, polyvinyl chloride sheathed flame-retardant the main loop of the inverter with cable, 3 x 185 + 3 x 35 was expressed as: BPYJVP - 0.6/1 kv 3 x 185 + 3 x 35 note: detailed technical parameters of ball I on cable company LTD.
万用表电流档分为交流档与直流档两个,当测量电流时,必须将万用表指针打到相应的档位上才能进行测量。交流档直流档在测量电流时,若使用mA档进行测量,须把万用表黑表笔插在COM孔上,把红表笔插在mA档上,如下图方框所示;若使用10A档进行测量,则黑表笔不变,仍插在COM孔上,而把红表笔拔出插到10A孔上,如下图方框所示。电流测量注意事项如果使用前不知道被测电流范围,将功能开关置于最大量程并逐渐降低量程(不能在测量中改变量程)。
接地线选用黄绿双色线,接开关线选用红、黄、蓝、绿、黑等任一种。2000年后,电路设计一般是:进户线6—10mm2,照明2.5mm2,插座4mm2,空调6mm2专线。单芯电线1.5平方电线,用于灯具照明,单芯电线2.5平方电线,用于插座。

变频器与变频电机问电缆均需采用对称电缆结构,对称电缆结构有3芯和3+3芯两种,3+3芯电缆结构是将三大一小四芯绝缘线芯中第四芯(中性线芯)分解为三个截面较小的绝缘线芯,把三大三小线芯对称成缆,对于6/10kV变频电机专用电缆,该电缆结构与6/10kV普通电力电缆有所不同,普通电力电缆是将三根绝缘线芯。