pxr3温控器简介:
◆单排显示,pv、sv可相互切换;
◆多种热电偶信号、热电阻信号、线形信号输入;
◆带手/自动模式,切换便利;
◆8段斜坡/保温程序(选件)
◆满量程0.5%精度,85-256v ac 50/60hz供电工作。
◆再传输输出功能dc4-20ma和rs485通讯功能(选件)
◆遥控输入功能(选件)
◆数字量输入最多2点(选件):通过一点开关量on/off,可改变设定值sv,控制动作起/停,斜坡/保温控制的开始/复位,自动调节功能的起/停,报警锁存的复位、定时器计时开始;
◆二路输出(选件):用于加热/冷却控制
◆加热断线报警(选件)
◆自带一路报警功能:最多2点(选件)。
|
pxr3系列选型表
|
||||||||||||||
|
数字位
|
规格
|
代号
|
|
|||||||||||
|
4
|
5
|
6
|
7
|
8
|
-
|
9
|
10
|
11
|
12
|
13
|
-
|
14
|
||
|
4
|
面板尺寸 h*w
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
24*48
|
3
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5
|
输入信号
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
热电偶(℃)
|
|
t
|
|
|
|
|
|
|
|
|
|
|
|
|
|
热电偶(f)
|
|
r
|
|
|
|
|
|
|
|
|
|
|
|
|
|
rtd/pt100(℃)
|
|
n
|
|
|
|
|
|
|
|
|
|
|
|
|
|
rtd/pt100(f)
|
|
s
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1~5v dc
|
|
a
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4~20ma dc
|
|
b
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6
|
控制输出1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
继电器接点输出
|
|
|
a
|
|
|
|
|
|
|
|
|
|
|
|
|
ssr/ssc驱动输出
|
|
|
c
|
|
|
|
|
|
|
|
|
|
|
|
|
4~20ma dc输出
|
|
|
e
|
|
|
|
|
|
|
|
|
|
|
|
|
7
|
控制输出2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
无
|
|
|
|
y
|
|
|
|
|
|
|
|
|
|
|
|
继电器接点输出 注1
|
|
|
|
a
|
|
|
|
|
|
|
|
|
|
|
|
ssr/ssc驱动输出 注1
|
|
|
|
c
|
|
|
|
|
|
|
|
|
|
|
|
4~20ma dc输出 注1
|
|
|
|
e
|
|
|
|
|
|
|
|
|
|
|
|
8
|
版本号
|
|
|
|
|
1
|
-
|
|
|
|
|
|
|
|
|
9
|
附加功能1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
无报警
|
|
|
|
|
|
|
0
|
|
|
|
|
|
|
|
|
1个报警
|
|
|
|
|
|
|
1
|
|
|
|
|
|
|
|
|
8段斜坡/保温程序
|
|
|
|
|
|
|
4
|
|
|
|
|
|
|
|
|
1个报警+8段斜坡/保温程序
|
|
|
|
|
|
|
5
|
|
|
|
|
|
|
|
|
两个报警 注2
|
|
|
|
|
|
|
f
|
|
|
|
|
|
|
|
|
两个报警+8段斜坡/保温注2
|
|
|
|
|
|
|
g
|
|
|
,
|
|
|
|
|
|
10
|
操作说明书 电源电压
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
无 100-240v
|
|
|
|
|
|
|
|
n
|
|
|
|
|
|
|
|
日文 100-240v
|
|
|
|
|
|
|
|
y
|
|
|
|
|
|
|
|
英文 100-240v
|
|
|
|
|
|
|
|
v
|
|
|
|
|
|
|
|
无 24vac/24vdc
|
|
|
|
|
|
|
|
c
|
|
|
|
|
|
|
|
日文 24vac/24vdc
|
|
|
|
|
|
|
|
a
|
|
|
|
|
|
|
|
英文 24vac/24vdc
|
|
|
|
|
|
|
|
b
|
|
|
|
|
|
|
|
11
12
13
|
附加功能2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
无
|
|
|
|
|
|
|
|
|
0
|
0
|
0
|
|
|
|
|
rs485 (modbus)通讯
|
|
|
|
|
|
|
|
|
m
|
0
|
0
|
|
|
|
|
rs485 (z-asc11)通讯
|
|
|
|
|
|
|
|
|
n
|
0
|
0
|
|
|
|
|
再传输输出+1点数字输入 注3
|
|
|
|
|
|
|
|
|
q
|
0
|
0
|
|
|
|
|
再传输输出 注3
|
|
|
|
|
|
|
|
|
r
|
0
|
0
|
|
|
|
|
2点数字输入
|
|
|
|
|
|
|
|
|
t
|
0
|
0
|
|
|
|
|
rs485(modbus)通讯+1点数字输入
|
|
|
|
|
|
|
|
|
v
|
0
|
0
|
|
|
|
|
rs485(z-asc11)通讯+1点数字输入
|
|
|
|
|
|
|
|
|
w
|
0
|
0
|
|
|
|
|
14
|
无标准功能
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
无标准参数设定(非标)
|
|
|
|
|
|
|
|
|
|
|
|
-
|
f
|
|
|
注1:两个过程报警(即选项9中的f和g)不能一起选
|
||||||||||||||
|
注2:控制输出2(即选项7中的a、c、e)不能一起选
|
||||||||||||||
|
注3:控制输出2,两个报警和24v电源(即选项7中的a、c、e、选项9中的f和g,选项10中的a、b、c)不能一起选。
|
||||||||||||||