邢台WD-MKYJYP2矿用无卤低烟控制电缆复苏
在使用RS485通讯时,对于特定的传输线路,主机(召测设备)到仪表的485口间的电缆长度与数据信号传输的波特率成反比;这个长度主要受信号的失真以及噪声的影响所影响。理论上RS485的传输距离能达到1200米,但实际应用中传输距离要小于1200米,具体长度受周围的环境影响。
适用于矿用控制电缆适用于交流额定电压u0/u为450/750V及以下的控制监控回路及保护线路和配电装置中电器仪表的连接线。执行标准:MT818-2009.1 MT386-1995 Q/TX001-2006 严格按照煤矿安全有关规定。
我们厂生产的矿用控制电缆型号规格范围使用场合MKVV,MKVVP,MKVVP2 0.5-10mm2,2-61芯,适用于弱电控制系统或强电磁场干扰区MKVV22,MKVV20 0.5-10mm2,4-61芯 MKVV32,MKVV30 0.5-10mm2,7-61芯 MKVVR 0.5-6mm2,2-61芯 MKVVRP 0.5-4mm2,2-61芯 MKVVP22,MKVVP2-22 1.5-10mm2,4-61芯 MKVVP2-22-1 1.5-10mm2,4-61芯,主要用于500KV变电站与发电厂配电装置及强电磁场干扰区。
The sequence table of 200 pairs of communication cables (log-log cables) shows that there are 4 kinds of marking lines in 100 pairs of communication cables, and 25 pairs of marking lines are wrapped with the marking line of "bailan". The second 25 pairs are wrapped in "white orange" lines! The third 25 pairs are wrapped in "white and green" lines! The fourth 25 pairs are wrapped in "white brown" lines! The fifth 25 pairs are wrapped in a "white grey" logo line! The sixth 25 pairs are wrapped in a "red orchid" logo line! The seventh of the 25 pairs is wrapped in a red orange logo line! The eighth 25 pairs are wrapped in "red and green" lines! Manufacuring HYA; HYA22; HYA23; HYA53; ZRC - manufacuring HYA; ZRC - HYA53HYAT; HYAT23; HYAT53; HYAT22; HYYT; ZRC - HYAT; WDZ - HYAT; ZR - HYAT53; ;

一、阻燃本安安全系统用检测仪器电缆1、性能特性:a、电缆长期工作温度:70℃b、最低环境温度:-40℃c、电缆敷设温度:不低于0℃d、敷设时允许弯曲半径:不小于电缆外径6倍,铠装型电缆则应不小于电缆外径的12倍e、额定电压:300/500V2、电缆的型号、名称、适用范围:型号名称适用范围ZR-B。
详看图纸说明拿到图纸后,首先要仔细阅读图纸的主标题栏和有关说明,比如图纸目录,技术说明,元件明细表,施工说明书等等,结合自己已有的电工知识对该电气图的类型,性质,作用有一个明确的认识,从整体上理解图纸的概况和所要求表述的重点。阅读系统图和框图系统图和框图是用符号和带注释的框概略表示系统或分系统的基本组成,相互关系及其主要特征的一种简图。由于系统图和框图只是概略表示系统的组成,关系及特征,因此紧接着就要详细阅读电路图,才能搞清他们的工作原理。
它的使用特性经国家检测为煤矿用控制电缆导体的长期允许工作温度为70℃,电缆敷设温度应不低于0℃。煤矿用控制电缆允许的弯曲半径:对有铠装或铜带屏蔽结构的电缆应不小于电缆外径的12倍。对有屏蔽层结构的软电缆,应不小于电缆外径的6倍。对无铠装层的电缆应不小于矿用电缆外径的6倍。WD-MKYJYP2矿用无卤低烟控制电缆
MKVV电缆,MKVVP电缆,MKVVP2电缆,MKVV22电缆,MKVV32电缆,MKVVR电缆,MKVVRP电缆,MKVVP22电缆等规格型号的煤矿用阻燃控制电缆,推荐电缆芯数为2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52,61芯
MKVV(2-14)*(4-6)mm2
,(2-10)*10mm2 (2-61)*(0.75-2.5)mm2 MKVV22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2
MKVVP(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2
MKVVP22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 。
Armoured communication cable armoring cable type: HYA53, HYAT53, HYA23 HYAT23, HYV22, HYA22 (rat, buried) armoring communication cable USES: armoured communication cable mechanical protective layer can be appended to the structure of the cable, with the mechanical strength of the cable, antierosion capability, is vulnerable to mechanical and designed and vulnerable to erosion area telephone cable. Any kind of laying can be adopted, which is more suitable for direct buried laying in rock area. Armored communication cable structure: 1. Basic cable: any filled and unfilled cable with single sheath or double sheath structure. 2. Armored communication cable mechanical protection layer: type 53 adopts 0.15mm thick corrugated steel belt, which is longitudinal wrapped on the basic cable and overlapped on both sides. The surface of the steel belt is coated with plastic to prevent corrosion and water intrusion. The type 23,22 has similar performance with double steel band wrapping. 3. Armored communication cable sheath: black high-molecular weight low-density polyurethane or polyurethane sheath. Sheath thickness may depend on the basic cable outer diameter. 5. The marking contents of armored communication cables include: wire diameter, number of wire pairs, cable model, length, manufacturer name and year of manufacture. 6. Armored communication cable electrical characteristics: the cable meets all the electrical requirements of the basic cable. 6. Cable length: mechanically protected cable is made according to the length of the corresponding basic cable

3、安装敷设环境温度:≥0度,固定敷设时环境温度不低于-10度。4、电缆允许最小弯曲半径:≥15D(D-电缆外径)。●产品性能1、设计采用符合GB/T规定的第5类软绞合铜导体。2、交联聚乙烯绝缘、耐温耐候性好。
但如果积水过多,依旧会产生电管进水的情况。如果把水电管都安装在顶上(依然是电管在水管上方),无论水管怎么漏水,电管都不会有进水的风险——除非漏出的水把整个房间都泡起来,当然,这种情况的可能性微乎其微。管道走顶的坏处坏处耗材增加上文说到,管道走顶的做法是取消所有墙面上的横向开槽,改为纵向开槽。且水管走顶,为了固定起来更方便,需要沿着墙壁走管,距离也就更长。这样一来,势必会造成耗材的浪费——增加不少管件的用量。
该电缆主要用于交流或直流300V及以下的工作系统,在500V及以下时能正常工作。金属屏蔽电力电缆适用于额定电压0.6/1kv及以下的交直流电力系统中的输送电能用。产品具有较强的电磁干扰、抗雷击及均衡电位、改善供电品质的特性,特别适宜计算机中心、航空航天监控中心、智能大楼等精密电子装置的场所。
矿用控制电缆:1、额定电压450/750v 2、电缆导体的长度允许工作温度为70摄氏度 3、电缆的敷设温度应不低于0摄氏度,推荐的允许弯曲半径; 4、无铠装层的电缆,应不小于电缆外径的6倍 5、有铠装或铜带屏蔽结构的电缆,应不小于电缆外径的12倍,6、有屏蔽结构的软电缆,应不小于电缆外径的6倍,
MT386-1995《煤矿用阻燃电缆阻燃性的试验方法和判定规则》及Q/TX 001-2006 《煤矿用塑料绝缘控制电缆》 。