赛特蓄电池BT-HSE-100-12 全系列产品简介
赛特蓄电池BT-HSE-100-12 全系列产品简介
赛特蓄电池BT-HSE-100-12 全系列产品简介
赛特蓄电池主要技术特点:
Main technical features of Saite battery:
1、不需维护:
1. No maintenance required:
电池在整个使用寿命期间无需加水补液。可靠性高、使用寿命长,特殊的密封结构和阻燃外壳,在使用过程中不会产生泄漏电解液的缺陷,更不会发生火灾。
There is no need to add water to the battery during the whole service life. High reliability, long service life, special sealing structure and flame-retardant shell, in the use process will not produce leakage of electrolyte defects, not to mention fire.
2、重量、体积比能量高,内阻小,输出功率高:
2. High specific energy of weight and volume, small internal resistance and high output power:
自放电小,20℃下每月的自放电率不大于2%。?满荷电出厂,无流动的电解液,运输安全。
The self discharge rate is less than 2% per month at 20 ℃. ? leave factory with full charge, no flowing electrolyte, safe transportation.
3、使用温度范围广:
3. Wide temperature range:
标准系列电池(-30℃~50℃),高温系列(-45℃~70℃)?无需均衡充电,由于单体电池的内阻、容量,浮充电压一致性优良,确保了电池在使用期?间,无需均衡充电。
Standard series batteries (- 30 ℃ ~ 50 ℃) and high temperature series (- 45 ℃ ~ 70 ℃)? Do not need to be charged evenly. Due to the internal resistance, capacity and good consistency of floating charge voltage of single battery, it is ensured that the battery does not need to be charged evenly during its service life.
4、恢复性能好:
4. Good recovery performance:
将电池过放电至0伏,短路放置30天后,仍可充电恢复其容量。坚固的铜??端子:便于安装连接,导电能力强。
When the battery is over discharged to 0 V and short circuited for 30 days, it can still be charged to restore its capacity. Solid copper? Terminal: easy to install and connect, strong conductivity.
赛特蓄电池主要应用领域:
Main application fields of Saite battery:
1、计算机辅助设计和计算机控制主要生产过程,确保产品性能的一致性并达到设计标准
1. Computer aided design and computer control the main production process to ensure the consistency of product performance and meet the design standards
2、应用太阳能光伏系统,路灯及城市亮化工程,风力发电储能,风光互补路灯,庭院灯,航标灯,信号灯,发电厂,变电站?,电信,通讯,电力,核电站,水电站。
2. Solar photovoltaic system, street lamp and urban lighting engineering, wind power generation and energy storage, landscape complementary street lamp, courtyard lamp, beacon lamp, signal lamp, power plant, substation, telecommunication, communication, power, nuclear power plant, hydropower station.
、UPS不间断电源,EPS应急电源,微波中继站,备用电源,所有直流电源、交流直流逆变系统,铁路机车车辆,电动车,船舶,电动游艇,电动船,交换机,应急照明,煤矿防爆牵引,电瓶车,叉车,汽车起动,照明,防火,警报,医疗,遥测设备,安全系统,手提式电源,可携式电动器具,泵系统等
3. UPS uninterruptible power supply, EPS emergency power supply, microwave relay station, standby power supply, all DC power supply, AC DC inverter system, railway rolling stock, electric vehicle, ship, electric yacht, electric ship, switch, emergency lighting, coal mine explosion-proof traction, battery car, forklift, car start, lighting, fire protection, alarm, medical, telemetry e, safety system, portable Type power supply, portable electric appliance, pump system, etc
备注:以上可以根据客户要求制作不同规格
Note: the above specifications can be made according to customer re
泉州赛特蓄电池BT-HSE-70-12南京代理价格
Saite battery bt-hse-70-12 Nanjing agency price
赛特蓄电池BT-HSE-100-12 全系列产品简介
上海某供电局UPS供电局,负责上海某区的电力调度及监控,该供电局自启动数字化监控系统以来,前后经过两次UPS供电扩容改造,因负载容量逐步扩大,此次系统将进一步扩容,并对原有系统配电进行改造。同时由于设计施工不规范,系统存在重大隐患, 此次扩容需一并解决。
1.系统配置
如图一所示:该供电局配置两路市电,分别由交流进线屏1和交流进线屏2向UPS供电,两个交流进线屏间由一个手动切换屏,可以进行切换。1#UPS和2#UPS为M品牌的15KVA 1+1并机系统,3#UPS为A品牌UPS,设计容量为15KVA。交流进线屏1向3#UPS和2#UPS供电,交流进线屏向1#UPS供电。
2.系统存在的几个重大缺陷
a.1#UPS和2#UPS组成并机,但是分别由进线屏1(市电1)和进线屏2(市电2)分别供电,造成UPS转旁路时,并机系统会存在两路市电,造成短路,严重威胁整个系统安全。
b.由于1#UPS和2#UPS的交流输入分别来自不同回路的市电,可能出现其中一路交流输入故障,致使一台UPS工作于正常状态,另一台工作于后备状态,造成两套UPS逆变输出并机环流增大,负载均分误差增大,引发UPS故障。
c.如图二所示,整个存在一个共同的维修旁路(由K10、K11、K12组成)。由于三台UPS的交流输入分别来自不同两路市电,,所以存在不同市电回路短路的危险,真正维护时也无法实现不停电维护。同时也存在因人员操作,引起短路的危险
图二、原系统内部走线示意图
二、客户需求
1.对现有UPS系统进行扩容,移除原有的3#UPS,新增两台30KVA UPS组成1+1并机,并对现有配电屏进行改造。
2.合理投资方案,同时减少占地面积。
3.設置一个共同的维护旁路,要求4套UPS能够同时维护检修。
4.在系统中留出一定余量的配置,供以后扩展需求。
三、改造方案
经与该供电局工程师进行详细沟通,并实地考察后,我司多名工程师,根据要求,拟制了一份详细的改造方案,方案涵盖了UPS设备选型,配电改造,施工等部分全部内容,其中UPS部分改造方案如下:
1、两路市电,经ATS切换屏后,二选一供给负载及UPS使用。
2、新增台达NT30KVA UPS两套(3#、4#),组成1+1并机。
3、采用共用电池组方案,大限度优化投资方案,同时减少空间占用。
4、所有UPS旁路取A相,保证任一时刻,并机系统内两台UPS均在同一路市电状态。
5、1#UPS、2#UPS组成的并机系统、3#、4#组成的并机系统分别设置一个维修旁路。两个维护旁路中间设一个联络开关,必要时闭合次开关,使所有UPS处于维修旁路供电状态。
6、两路UPS并机输出配电屏,各预留一组C65-20断路器,预备后期系统负载扩容需求。